NGT-B Specifications

Mechanical specifications are based on tool mounted in pressure barrel and GO Pin connections. Custom options available.

MechanicalDiameter (OD)1 11/16” (available in 1 3/8”, NGT-S)
Length (make-up)22.25”
Weight6.8 lb.
End ConnectorsGO Single Pin
MaterialTi-6Al-4V Titanium
PerformanceSensitivity/Range1.8 counts per API/0-10,000 API
Accuracy+/- 10% at 175°C
Thin-Bed Resolution (7″ casing diameter, at 50% points)6.2”
EnvironmentalOperating Temperature175°C (350°F)
Survival Temperature204°C (400°F)
Max. Temperature Ramp Rate5°F per minute
Vibration (3 axis); 50-300 Hz, Random30 GRMS
Shock (Z axis)250 G, 0.5 mSec.
Shock (X or Y axis)500 G, 0.5 mSec.
Pressure15,000 psi
Power RequirementsInput Voltage46-48 VDC, 50VDC Max.
Input Current20mA
Output SignalPulse+5V to GND, 5 uSec width

NGT-S Specifications

Mechanical specifications are based on tool mounted in pressure barrel and GO Pin connections. Custom options available.

MechanicalDiameter (OD)1 3/8”
Length (make-up)25.20”
Weight4.0 lb.
End ConnectorsGO Single Pin
MaterialTi-6Al-4V Titanium
PerformanceSensitivity/Range1.5 counts per API/0-10,000 API
Accuracy+/- 10% at 175°C
Thin-Bed Resolution (7″ casing diameter, at 50% points)6.2”
EnvironmentalOperating Temperature175°C (350°F)
Survival Temperature204°C (400°F)
Max. Temperature Ramp Rate5°F per minute
Vibration (3 axis); 50-300 Hz, Random20 GRMS
Shock (Z axis)250 G, 0.5 mSec.
Shock (X or Y axis)500 G, 0.5 mSec.
Pressure15,000 psi
Power RequirementsInput Voltage46-48 VDC, 50VDC Max.
Input Current20mA
Output SignalDigital Telemetry or Pulse+5V to GND, 5 uSec width