NGT-B Specifications

Mechanical specifications are based on tool mounted in pressure barrel and GO Pin connections. Custom options available.

Mechanical Diameter (OD) 1 11/16” (available in 1 3/8”, NGT-S)
Length (make-up) 22.25”
Weight 6.8 lb.
End Connectors GO Single Pin
Material Ti-6Al-4V Titanium
Performance Sensitivity/Range 1.8 counts per API/0-10,000 API
Accuracy +/- 10% at 175°C
Thin-Bed Resolution (7″ casing diameter, at 50% points) 6.2”
Environmental Operating Temperature 175°C (350°F)
Survival Temperature 204°C (400°F)
Max. Temperature Ramp Rate 5°F per minute
Vibration (3 axis); 50-300 Hz, Random 30 GRMS
Shock (Z axis) 250 G, 0.5 mSec.
Shock (X or Y axis) 500 G, 0.5 mSec.
Pressure 15,000 psi
Power Requirements Input Voltage 46-48 VDC, 50VDC Max.
Input Current 20mA
Output Signal Pulse +5V to GND, 5 uSec width

NGT-S Specifications

Mechanical specifications are based on tool mounted in pressure barrel and GO Pin connections. Custom options available.

Mechanical Diameter (OD) 1 3/8”
Length (make-up) 25.20”
Weight 4.0 lb.
End Connectors GO Single Pin
Material Ti-6Al-4V Titanium
Performance Sensitivity/Range 1.5 counts per API/0-10,000 API
Accuracy +/- 10% at 175°C
Thin-Bed Resolution (7″ casing diameter, at 50% points) 6.2”
Environmental Operating Temperature 175°C (350°F)
Survival Temperature 204°C (400°F)
Max. Temperature Ramp Rate 5°F per minute
Vibration (3 axis); 50-300 Hz, Random 20 GRMS
Shock (Z axis) 250 G, 0.5 mSec.
Shock (X or Y axis) 500 G, 0.5 mSec.
Pressure 15,000 psi
Power Requirements Input Voltage 46-48 VDC, 50VDC Max.
Input Current 20mA
Output Signal Digital Telemetry or Pulse +5V to GND, 5 uSec width