NGT-100 Gamma Tool (182°C)

NGT-100

Ruggedized, Gamma Tool (1.0”)

208-000-000-min

The 1.0” diameter NGT-100 is CBG’s next generation small diameter gamma that is ideally suited for mounting within drill-collar walls for azimuthal gamma or bulk gamma applications. New patent pending electrical and mechanical designs push the operating temperature to 182°C, improve shock and vibration performance.

Electronics

The NGT-100 contains CBG’s new patent pending electronics designs.  Encapsulated and cushioned within pre-molded high-temperature silicone pads, the printed circuit boards are protected from extreme shock and vibration.  A new and innovative technique for providing electronics temperature compensation ensures a more stable output signal through the full range of operating temperatures.  A burst filter has been added to reduce spurious counts that can result from excessive shock and vibration, as well as external transient noise. 

Mechanical

Included in the NGT-100 is a new patent pending approach to mounting the crystal and phototube for improved shock and vibration performance.  The circuit boards and wiring are enclosed beneath metal covers preventing exposure to external noise and physical damage.

NGT-100

Ruggedized, Gamma Tool (1.0”)

208-000-000-min

The 1.0” diameter NGT-100 is CBG’s next generation small diameter gamma that is ideally suited for mounting within drill-collar walls for azimuthal gamma or bulk gamma applications. New patent pending electrical and mechanical designs push the operating temperature to 182°C, improve shock and vibration performance.

Electronics

The NGT-100 contains CBG’s new patent pending electronics designs.  Encapsulated and cushioned within pre-molded high-temperature silicone pads, the printed circuit boards are protected from extreme shock and vibration.  A new and innovative technique for providing electronics temperature compensation ensures a more stable output signal through the full range of operating temperatures.  A burst filter has been added to reduce spurious counts that can result from excessive shock and vibration, as well as external transient noise. 

Mechanical

Included in the NGT-100 is a new patent pending approach to mounting the crystal and phototube for improved shock and vibration performance.  The circuit boards and wiring are enclosed beneath metal covers preventing exposure to external noise and physical damage.

NGT-100 Specifications

P/N 208-000-000

Detector Scintillator Crystal Sodium Iodide, Na(TI)
Photomultiplier Hamamatsu R3991A
Mechanical Diameter (OD) 1.0” w/out shrink tubing sleeve
1.04” w/shrink tubing sleeve
Length (make-up) 12.0”
Weight 14 oz.
Connectors Flying lead (PWR, GND, Signal Out)
Material Aluminum Alloy
Performance Sensitivity 1.25 CPS/API
Accuracy +/- 5% to 150°C
+/- 10% 150°C to 182°C
Environmental Temperature (Operating) -18°C to 182°C
Temperature (Survival) w/ reduced accuracy -40°C to 200°C
Temperature ramp rate 2.8°C (5°F) per minute
Vibration (3 axis) 50-1000 Hz, Random 30G (20G RMS)
Shock (3 axis) 750G, 0.5 ms, half-sine
Burst Filter Reduces spurious counts due to extreme shock/vibration and external system electronic noise.
Power Requirements Power (DC input Voltage) 10v-50v, 60v Max
Tool Current 8-11mA
Output Signal Output Signal Negative Pulse, +5V to GND, 5 usec pulse width
MWD Tools | Gamma Sensors

© CBG Corp All Rights Reserved | Terms of Use | Privacy Policy