NGT-TX Gamma Tool
NGT-TX
1.36″ OD Gamma Tools
The NGT-TX gamma tool is a shorter version of the NGT-T tool. 2.0” have been removed from the electronics chassis for an overall make-up length of 11.6”. All other specifications are the same as the NGT-T.
To protect your gamma investment and ensure the best performance use CBG original SNB Snubbers-Shock & Vibration Isolators.


NGT-TX
1.36″ OD Gamma Tools
The NGT-TX gamma tool is a shorter version of the NGT-T tool. 2.0” have been removed from the electronics chassis for an overall make-up length of 11.6”. All other specifications are the same as the NGT-T.
To protect your gamma investment and ensure the best performance use CBG original SNB Snubbers-Shock & Vibration Isolators.
NGT-TX Specifications
Detector | Nal(TI) Scintillator Crystal | 1.0” Diameter X 4.0” Length |
---|---|---|
Photomultiplier | R3991A (Hamamatsu) | |
Mechanical | Diameter (OD) | 1.36” |
Length (make-up) | 11.6” | |
Weight | 1.5 lb. | |
End Connectors | Micro-D Subminiature, 15-Pin | |
Material | Aluminum Alloy | |
Performance | Sensitivity | 1.14 CPS/API* |
Accuracy | +/- 5% to 300°F +/- 10% to 350°F |
|
Thin-Bed Resolution (8” hole Diameter) | 6.8” | |
Environmental | Operating Temperature | 0°F to 350°F |
Survival Temperature (reduced accuracy) | -40°F to 400°F | |
Heat/Cool Rate, Max. | 5°F per minute | |
Vibration (3 axis) 50-1000Hz, Random | 20G RMS | |
Shock (3 axis) | 1000G, 0.5ms, half-sine | |
Power Requirements | DC Input Voltage | 17-48 VDC, 50VDC Max. |
Tool Current | 8-11 mA | |
Output Signal | Negative Pulse | +5V to GND, 5 uSec width |
* Counts are collected with gamma tool mounted within standard BeCu pressure barrel, (OD 1.875″, ID 1.500″). API Calibration performed with AEA Technology, QSA Inc., KUTh Field Verifier #188074, S/N 255 Radionuclides: K-40(11.7%), U-238(90 ppm), Th-232(40 ppm).
© CBG Corp All Rights Reserved | Terms of Use | Privacy Policy