NGT-CSX-B Gamma Tool (175°C)
NGT-CSX-B
Gamma Tool (1.05” OD)
The NGT-CSX-B is ideal for either probe based or collar mounted assemblies used in azimuthal gamma or bulk gamma applications due to sensitivity similar to larger diameter gamma tools. Encapsulated and cushioned within pre-molded high-temperature silicone pads, the printed circuit boards are protected from extreme shock and vibration.


NGT-CSX-B
Gamma Tool (1.05″ OD)
The NGT-CSX-B is ideal for either probe based or collar mounted assemblies used in azimuthal gamma or bulk gamma applications due to sensitivity similar to larger diameter gamma tools. Encapsulated and cushioned within pre-molded high-temperature silicone pads, the printed circuit boards are protected from extreme shock and vibration.
NGT-CSX-B Specifications
P/N 205-200-000
Detector | Scintillator Crystal | Sodium Iodide, Na(TI) |
---|---|---|
Photomultiplier | R3991A (Hamamatsu) | |
Mechanical | Diameter (OD) | 1.05” |
Length (make-up) | 15.5” | |
Weight | 1.5 lb. | |
End Connectors | Micro-D Subminiature, 15-Pin | |
Material | Aluminum Alloy | |
Performance | Sensitivity | 1.48 CPS per API |
Accuracy | +/- 5% to 150°C +/- 10% to 175°C |
|
Environmental | Operating Temperature | -18°C to 175°C |
Survival Temperature (reduced accuracy) | -40°C to 200°C | |
Heat/Cool Rate, Max. | 2.8°C (5°F) per minute | |
Vibration (3 axis) 50-1000Hz, Random | 30G (20G RMS) | |
Shock (3 axis) | 1000G, 0.5ms, half-sine | |
Power Requirements | DC Input Voltage | 17-48 VDC, 50VDC Max. |
Tool Current | 8-11 mA | |
Output Signal | Negative Pulse | +5V to GND, 5 uSec width |